RS485 Modbus Automatic Clean UV254 Sewer Water Sensor Chemical Oxygen Demand Cod

Still deciding? Get samples of $ !
Order Sample
Product Details
Customization: Available
After-sales Service: Yes
Warranty: 3 Years
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
  • visa
  • mastercard
  • discover
  • JCB
  • diners club
  • american express
  • T/T
  • PIX
  • SPEI
  • OXXO
  • PSE
  • OZOW
  • PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Self-branded
The supplier has 3 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 3 patents, you can check the Audit Report for more information
to see all verified strength labels (26)
RS485 Modbus Automatic Clean UV254 Sewer Water Sensor Chemical Oxygen Demand Cod pictures & photos
RS485 Modbus Automatic Clean UV254 Sewer Water Sensor Chemical Oxygen Demand Cod pictures & photos
  • RS485 Modbus Automatic Clean UV254 Sewer Water Sensor Chemical Oxygen Demand Cod
  • RS485 Modbus Automatic Clean UV254 Sewer Water Sensor Chemical Oxygen Demand Cod

Find Similar Products

Overview

Basic Info.

Model NO.
SQ800-01COD
Display
Digital
Appliance
Wastewater Treatment
Portable
Non Portable
Certification
RoHS, CE
Type
Cod Meter
Function 1
Water Quality Monitor
Funciton 2
Cod Wastewater Treatment
Function 3
Wireless Cod Monitoring
Function 4
Water Quality Sensor
Transport Package
Carton Box
Specification
20*14*8
Origin
China
HS Code
9032890000
Production Capacity
1000PCS/Month

Packaging & Delivery

Package Size
25.00cm * 25.00cm * 15.00cm
Package Gross Weight
3.000kg
Lead Time
7 days (1 - 10 Pieces)
To be negotiated ( > 10 Pieces)

Product Description

COD Sensor for Wastewater Treatment
      The COD Sensor is a digital sensor featuring an easy-to-integrate RS485 communication interface and standard Modbus protocol. It is equipped with a corrosion-resistant housing, IP68 protection rating, and a built-in self-cleaning brush for periodic cleaning of the measurement interface, making it suitable for harsh working environments. Utilizing long-life LED light sources and beam measurement technology, it ensures high measurement precision and stability.
RS485 Modbus Automatic Clean UV254 Sewer Water Sensor Chemical Oxygen Demand Cod
Features
1. Features a corrosion-resistant titanium alloy housing
2. NPT 3/4 threaded interface for easy installation
3. It employs dual-beam measurement technology to simultaneously monitor parameters such as COD and turbidity
4. Operating without chemical reagents, it ensures rapid measurement, no secondary pollution
5. Equipped with a program-controlled self-cleaning function, it effectively prevents debris sedimentation and bubble adhesion on the measurement interface
6. It supports plug-and-play operation with built-in calibration record storage, eliminating the need for initial calibration upon first use
RS485 Modbus Automatic Clean UV254 Sewer Water Sensor Chemical Oxygen Demand Cod
Operation principle
The fundamental measurement principle of the UV254 absorption method is based on the absorption of ultraviolet (UV) light by organic compounds in water samples to determine their content and composition.
Specifically, the UV absorption method involves directing UV light at a specific wavelength (254nm) into the water sample. The absorbance value obtained is then used to calculate the Chemical Oxygen Demand (COD) concentration in the water. This calculation relies on the Lambert-Beer Law, which serves as the foundational theoretical framework for measuring the absorbance of substances
RS485 Modbus Automatic Clean UV254 Sewer Water Sensor Chemical Oxygen Demand Cod
Installation
1. Avoid exposing the sensor to direct sunlight
2. Do not touch the measurement area of the sensor with bare hands
3. Ensure the sensor surface is free of air bubbles during measurement and calibration
4. Avoid applying mechanical stress (pressure, scratches, etc.) to the sensor during use
Technical Specification
(Custom configurations available upon request.)
Model
SQ800-01COD
Voltage
DC12V-DC24V
Measurement range
≤500mg/L,≤500NTU
Communication mode
RS485(Modbus RTU)
Measurement accurate
≤±5%
Protection rating
IP68
Measurement principle
UV254
Resolution
0.01mg/L
Repeatability
Below 3%
Extension cable
5m
Drift
Below 3%


Optical Path Length
20mm


RS485 Modbus Automatic Clean UV254 Sewer Water Sensor Chemical Oxygen Demand Cod
Company Profile
RS485 Modbus Automatic Clean UV254 Sewer Water Sensor Chemical Oxygen Demand Cod
RS485 Modbus Automatic Clean UV254 Sewer Water Sensor Chemical Oxygen Demand Cod
RS485 Modbus Automatic Clean UV254 Sewer Water Sensor Chemical Oxygen Demand Cod
RS485 Modbus Automatic Clean UV254 Sewer Water Sensor Chemical Oxygen Demand Cod
RS485 Modbus Automatic Clean UV254 Sewer Water Sensor Chemical Oxygen Demand Cod
Packaging & Shipping
RS485 Modbus Automatic Clean UV254 Sewer Water Sensor Chemical Oxygen Demand Cod
FAQ
Q: What's the lead time for orders?
A: Standard models ship in 15–30 days; customized units require 30–45 days.
Q: Do you provide after-sales service overseas?
A: Yes, we have partnered service centers in key regions.
Q: Can I request a customized order?
A: Absolutely! We offer OEM and ODM service.
Q: What documents do you provide for export?
A: Full export package (Commercial Invoice, Packing List, Bill of Lading, COC, etc.).
Q: How do I place an order?
A: Contact us via email/phone for a quote, then confirm with a PO.

Send your message to this supplier

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now